Horstmann C-Stat ZW User's Guide

Browse online or download User's Guide for Thermostats Horstmann C-Stat ZW. Horstmann C-Stat ZW User Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
C-Stat 17-ZW
User Instructions
7 Day Wireless Programmable Room
Thermostat and ASR-ZW Receiver
Programmable room thermostats are widely recognised as one
of the best ways in which to control central heating. Horstmann
C-Stat programmable room thermostats have a large display
and intuitive user interface, making them easy to set up and use.
C-Stat uses a sophisticated time proportional integral (TPI)
algorithm for accurate temperature control and energy
efficiency.
1
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - User Instructions

C-Stat 17-ZWUser Instructions7 Day Wireless Programmable Room Thermostat and ASR-ZW Receiver Programmable room thermostats are widely recognised as on

Page 2

Setting the PROGRAMMESix time and temperature settings are available in each 24 hour period. Pressing BACK at any time in this process will r

Page 3

To copy the same programmes to other days of the week, please follow the process belowSetting the STANDBYTo exit STANDBY mode, press ENTER TWICEWhen

Page 4

Setting the HOLIDAY programmePressing BACK at any time in this process will return you to normal operating modePress ENTER twiceThe START date

Page 5

If the holiday period START date matches today's date, the STANDBY temperature will be shown on the display together with the suitcase i

Page 6

Setting the TIME and DATEPressing BACK at any time in this process will return you to normal operating modeIf an incorrect date is entered the

Page 7 - PERMANENT OVERRIDE

SETUP MENUTo access the SET UP MENU take the following steps:MENU OPTIONSPress ENTER twicePress ENTERPress '-' or '+' to toggle be

Page 8

TPI cycles per hour This setting helps the TPI energy saving software to operate correctly depending on the type of heating system you haveOptimum sta

Page 9

Setting the DAYLIGHT SAVINGPressing BACK at any time in this process will return you to normal operating modeThe default factory setting is fo

Page 10

Settin g th e STANDBY TE MP ERATURE , LO WER TEMPERATURE LIMIT or UPPER TEMPERATURE LIMITPressing BACK at any time in this process will retu

Page 11 - Setting the STANDBY

Setting the TPI cyclesPressing the BACK at any time in this process will return you to normal operating mode Oil Boilers 3 cycles per hour Gas Boilers

Page 12 - Setting the HOLIDAY programme

What is a programmable room thermostat?...an explanation for householders.A programmable room thermostat is both a programmer and a room thermostat. A

Page 13

Setting the OPTIMUM STARTThis setting will allow the C-Stat to anticipate the next set temperature and switch on up to two hours in advance

Page 14 - Setting the TIME and DATE

Setting the TAMPER SETTINGThis setting allows the unit to be locked to the programmes set and can only be reactivated by entering the pin code.None of

Page 15 - MENU OPTIONS

Cancelling the TAMPER SETTINGPressing BACK at any time in this process will return you to normal operating modePress ENTER twicePress ENTERThe

Page 16 - MENU OPTIONS (Contd...)

RESETTING THE C-STATElectronic equipment can in some circumstances be affected by electrical interference.If the display becomes frozen or scrambled s

Page 17 - Setting the DAYLIGHT SAVING

Stage 1 – The battery low symbol will appear in the displayStage 2 – The words 'Low Battery' will appear in the display for 1 second each ti

Page 18

If your heating system is a boiler with radiators, there will usually be only one programmable room thermostat to control the whole house. But you c

Page 19

Actual Room TemperatureDay ofWeekTime ofDayUntil (Time)Then (Temp)EnterButton+ Button- ButtonBack ButtonSetTemperatureAntenna Symbol4DISPLAYC-Stat 17-

Page 20

DISPLAYActual Room Temperature This is the actual room temperature measured by the C-StatSet Temperature This is the temperature that the C-Stat

Page 21

TEMPORARY OVERRIDEA temporary temperature change can be made at any time. It is also possible to extend how long this temperature override is in opera

Page 22

PERMANENT OVERRIDEIn the 'HOLD' position the temperature can be overridden by pressing either the '-' or '+' buttons

Page 23 - BACK ENTER

SETTING UP THE C-STATUpon initial installation the C-Stat has the following factory default settingsSettings – Monday to FridayTime Target Tem

Page 24 - Part Number P84874 Issue 1

MAIN MENU To access the MAIN MENU take the following steps:MENU OPTIONSPress ENTER twicePress '-' or '+' to toggle between the m

Comments to this Manuals

No comments